Redefining Self-Tapping Technology

Background

 

In an effort to eliminate a separate bone tapping procedure during the preparation of an osteotomy site, tapping segments were added onto the body of what are termed “self-tapping” implants. In reality, these were merely implants augmented with a tap portion.

 

Increased Cutting Efficiency

Reduced Insertion Torque

Reduced Micromotion

 

 

BLOSSOM® DESIGN

 

BLOSSOM® is the Patent Pending cutting configuration incorporated into the macro-design of the latest generation of Intra-Lock® Dental Implants.

 

Unlike traditional tapping design features, BLOSSOM’s architecture is unique in that it incorporates at least one cutting surface on each thread. BLOSSOM’s engineering breakthrough enables the implant to continually slice through the bone with increased efficiency and minimal force.

Dental Implants enhanced with BLOSSOM® feature an integrated helical self-tapping configuration. This enables the implant to continually cut through the bone with increased efficiency and minimal force. Lower insertion torque with reduced micro motion...

 

Welcome to the New Cutting-Edge.

 

SHOP NOW

Redefining the Self-Tapping Implant

Two implants, differing only in cutting design, were tested in blocks engineered to simulate type II bone. Both blocks were prepared identically and included observational canals. Each implant was photographed as it was seated at 10 RPM. The illustrations above were derived from the test photographs.

 

The implant with conventional tapping features cut the bone in discreet segments as it was turned into the osteotomy site (Fig.1, 2). The bone chips remained compacted only in the flute portion throughout the entire seating.

 

The implants distinguished by BLOSSOM® were observed to have fewer and smaller chips as well as displaying an even distribution of particulate matter positioned over the entire surface of the implant.

 

The bone chips originating from the cutting threads were shown to act as nucleating sites for new bone formation in a published study. Blossom implant optical micrographs at 6 weeks in vivo shows bone around the Blossom implant

design presenting primary osteonic structures (arrows) in the healing chamber regions, along with bone chips embedded in newly formed bone.iv

Blossom implant optical micrographs at 6 weeks in vivo.

Comparative Analysis of design features:

The data on the left illustrates the amount of insertion torque required as various implants progress into simulated bone. A test was performed on three Intra-Lock implant designs to ensure the only difference would be cutting groove design. Thirty-six implants (Classic DT without cutting flutes, Classic DT with cutting flutes and DT with the BLOSSOM self-tapping feature) were tested in vitroi using simulated Type II bone.ii The implants were screwed into the test blocks, with the torque being measured on every full turn using a digital torque gauge. The results were statistically significantiii and are referenced on the charts on the right.

 

BLOSSOM significantly reduces insertion torque. The unique design of the threads, cutting surfaces and channels result in improved synchronicity, harmony and contact.